Disclaimer: The technical statements, support, information and recommendations contained herein are believed to be accurate as of the date hereof, but 1st-line Equipment, LLC does not make representations or warranties, express or implied, as to its accuracy, its completeness, or the results to be obtained. The information is being provided for informational purposes only and is intended for use by persons having adequate skill and expertise regarding the proper selection, use and application of the products and recommendations and at their own risk and discretion. 1st-line Equipment, LLC is not responsible for any injury or damages from such information. Please note that parts are available for purchase from 1st-line Equipment, LLC self service parts portal. These parts do not include any technical support. If you're unfamiliar with the technical aspects of repairing equipment, please contact a professional for proper evaluation. By continuing to read further, you agree to abide by all the terms and conditions on this website. If you disagree, please leave our website.
Below is an informational chart of the different statuses you will see on the PID controls.
You can also find this information on page 33 in the instruction manual.
| ON/OFF Pilot Light | Temperature Pilot Light | Steam Pilot Light | Screen | |
| Coffee mode | ||||
| Start-up | ON | Flashing 1Hz | OFF | Real Reading |
| Heating | ON | Flashing 1Hz | OFF | Pre-set coffee temp |
| Ready to work | ON | ON | OFF | Pre-set coffee temp |
| Steam mode | ||||
| Steam mode (heating) | ON | ON | Flashing 1Hz | Pre-set steam temp (Flashing) |
| Steam mode (start-up warming) | ON | ON | Flashing 2Hz | Pre-set steam temp |
| Steam mode (in service) | ON | ON | ON | Pre-set steam temp |
| On ending steam mode (cooling) | ON | Flashing 1Hz | ON | Pre-set coffee temp (Flashing) |
| Others | ||||
| Stand-by mode | ON | OFF | OFF | – |
| Dose control fault | ON | OFF | Flashing 2Hz | E01 |
| Coffee temp Probe fault | ON | Flashing 2Hz | Flashing 2Hz | E02 |
| Coffee exchanger fault | ON | Flashing 4Hz | Flashing 2Hz | E03 |
| Steam temp Probe fault | ON | Flashing 2Hz | Flashing 2Hz | E04 |
| Steam exchanger fault | ON | Flashing 2Hz | Flashing 4Hz | E05 |
| Internal fault | ON | OFF | OFF | E98 |