PID Lights & Alarms – Ascaso Dream PID

Disclaimer: The technical statements, support, information and recommendations contained herein are believed to be accurate as of the date hereof, but 1st-line Equipment, LLC does not make representations or warranties, express or implied, as to its accuracy, its completeness, or the results to be obtained. The information is being provided for informational purposes only and is intended for use by persons having adequate skill and expertise regarding the proper selection, use and application of the products and recommendations and at their own risk and discretion.

1st-line Equipment, LLC is not responsible for any injury or damages from such information. Please note that parts are available for purchase from 1st-line Equipment, LLC self service parts portal. These parts do not include any technical support. If you're unfamiliar with the technical aspects of repairing equipment, please contact a professional for proper evaluation.

By continuing to read further, you agree to abide by all the terms and conditions on this website. If you disagree, please leave our website.

Below is an informational chart of the different statuses you will see on the PID controls.

You can also find this information on page 33 in the instruction manual.

ON/OFF Pilot Light Temperature Pilot Light Steam Pilot Light Screen
Coffee mode
Start-up ON Flashing 1Hz OFF Real Reading
Heating ON Flashing 1Hz OFF Pre-set coffee temp
Ready to work ON ON OFF Pre-set coffee temp
Steam mode
Steam mode (heating) ON ON Flashing 1Hz Pre-set steam temp (Flashing)
Steam mode (start-up warming) ON ON Flashing 2Hz Pre-set steam temp
Steam mode (in service) ON ON ON Pre-set steam temp
On ending steam mode (cooling) ON Flashing 1Hz ON Pre-set coffee temp (Flashing)
Others
Stand-by mode ON OFF OFF
Dose control fault ON OFF Flashing 2Hz E01
Coffee temp Probe fault ON Flashing 2Hz Flashing 2Hz E02
Coffee exchanger fault ON Flashing 4Hz Flashing 2Hz E03
Steam temp Probe fault ON Flashing 2Hz Flashing 2Hz E04
Steam exchanger fault ON Flashing 2Hz Flashing 4Hz E05
Internal fault ON OFF OFF E98

Please note the above information is subject to copyright. It cannot be published by any means without the expressed written consent of 1st-line Equipment, LLC.