Steam Boiler Leak at Refill Fitting – Lelit PL92T Elizabeth

Disclaimer: The technical support below for information purposes only. 1st-line Equipment, LLC is not responsible for any injury or damages resulting from such information. Please note that parts are available for purchase from 1st-line Equipment. These parts do not include any technical support. If you’re not familiar with the technical aspects of repairing equipment, please order a diagnosis on our website.

By continuing to read further, you agree to abide by all the terms and conditions on this web site. If you do not agree, please stop here.


  • Power off your machine & disconnect the power plug. Allow the machine to cool.
  • Remove blue wire connection.
  • Remove larger nut from boiler (do not pull on rod upwards and do not remove upper nut from lower).
  • Wire brush rod on inside.
  • Please plumbers tape on thread of larger nut (usually 2-4 rounds).
  • Reconnect blue wire.
  • Plug in machine into wall outlet and test and check for any other leaks.