PID Lights & Alarms – Ascaso Dream PID

Disclaimer: The technical support below for information purposes only. 1st-line Equipment, LLC is not responsible for any injury or damages resulting from such information. Please note that parts are available for purchase from 1st-line Equipment. These parts do not include any technical support. If you're not familiar with the technical aspects of repairing equipment, please order a diagnosis on our website. By continuing to read further, you agree to abide by all the terms and conditions on this web site. If you do not agree, please stop here.

Below is an informational chart of the different statuses you will see on the PID controls.

You can also find this information on page 33 in the instruction manual.

ON/OFF Pilot Light Temperature Pilot Light Steam Pilot Light Screen
Coffee mode
Start-up ON Flashing 1Hz OFF Real Reading
Heating ON Flashing 1Hz OFF Pre-set coffee temp
Ready to work ON ON OFF Pre-set coffee temp
Steam mode
Steam mode (heating) ON ON Flashing 1Hz Pre-set steam temp (Flashing)
Steam mode (start-up warming) ON ON Flashing 2Hz Pre-set steam temp
Steam mode (in service) ON ON ON Pre-set steam temp
On ending steam mode (cooling) ON Flashing 1Hz ON Pre-set coffee temp (Flashing)
Others
Stand-by mode ON OFF OFF
Dose control fault ON OFF Flashing 2Hz E01
Coffee temp Probe fault ON Flashing 2Hz Flashing 2Hz E02
Coffee exchanger fault ON Flashing 4Hz Flashing 2Hz E03
Steam temp Probe fault ON Flashing 2Hz Flashing 2Hz E04
Steam exchanger fault ON Flashing 2Hz Flashing 4Hz E05
Internal fault ON OFF OFF E98