Disclaimer: The technical support below for information purposes only. 1st-line Equipment, LLC is not responsible for any injury or damages resulting from such information. Please note that parts are available for purchase from 1st-line Equipment. These parts do not include any technical support. If you're not familiar with the technical aspects of repairing equipment, please order a diagnosis on our website. By continuing to read further, you agree to abide by all the terms and conditions on this web site. If you do not agree, please stop here.

LCC Error Codes


Lelit-Alarm-00

Missing water into the tank.

There is no water into the tank. Remove the water tank from its housing (7). Fill the tank with water at room temperature. Reposition the tank in the housing.

No-Water-Warning-on-LCC-DisplayPlease make sure the float in the reservoir can move freely back and forth. The float can stick. The cap can be removed since it is held with friction. The float and its holding compartment should be cleaned with non-abrasive detergent and non-abrasive sponge and reassembled.Please make sure the tab is not broken under the reservoir. If the tab is broken, the water reservoir will need replacement.

With the tank that has a tab under the reservoir, listen for the click when placing the reservoir in its final position. If it does not click, the switch may be off center or not working (damaged with water which would require a replacement).

Also, disconnect and reconnect the black audio-type of wire under the machine frame and reservoir assembly to reset the water level sensor.


Lelit-Alarm-01

Temperature probe of the coffee boiler in short circuit.

The temperature probe of the coffee boiler is in short circuit. All the machine functions are disabled. Contact the service center.


Lelit-Alarm-02

Temperature probe of the coffee boiler is faulty or disconnected.

The temperature probe of the coffee boiler is faulty or disconnected. All the machine functions are disabled. Contact the service center.


Lelit-Alarm-03

Steam boiler filling alarm.

The steam boiler filling phase has exceeded the maximum time of 150 seconds.

Error 3 is the steam boiler not filling fast enough. The problem may be that water sits for more than 2 weeks inside the machine which causes a small build up or low water pressure.

Water line pressure to low. It needs to be 35-40 psi. When low, the pump is usually louder than normal.

Second, the solenoid valve or a related pipe to refill the boiler may have build up as well as the pump having build up. We would suggest running a descaler through the coffee boiler and steam boiler (through the hot water wand as it refills).
Never remove more than 4 ounces of water through the water wand as you can burn out the heating element.

Lastly, contact the service center.


Lelit-Alarm-04

Temperature probe of the steam boiler in short circuit. The display will alternately show the 04 Alarm and the icon of the machine ready to use.

The temperature probe of the steam boiler is in short circuit, the steam boiler functions will be disabled. The machine will be able to dispense just coffee and hot water. Contact the service center.


Lelit-Alarm-05

Temperature probe of the steam boiler is faulty or disconnected. The display will alternately show the 05 Alarm and the icon of the machine ready to use.

The temperature probe of the steam boiler is faulty or disconnected, the steam boiler functions will be disabled. The machine will be able to dispense just coffee and hot water. Contact the service center.