Ala di Vittoria
La Valentina Espresso Machines
The full automatic electronic model has
a touchpad that remembers how much water to dose through the grouphead
for espresso coffee and also one for the hot water dispernser. In addition,
the star button, which is used for programming the other buttons, can
be utilized as a semi-automatic model where the user starts and stops
the water through the espresso coffee grind by engaging/disengaging
the star button. For the first few weeks, we recommend using this model
as a semi-automatic until you find the right grind, the right tamp,
and the right amount of espresso coffee in the basket (a.k.a. dose).
Once these parameters are set, we then recommend programming the four
coffee dosage buttons. The hot water dosage button can be programmed
for dispensing hot water from the water wand. However, we recommend
that you do not program more than 4 ounces of hot water as the hot water
can exit the boiler faster than the pump can replenish the water in
the boiler. If the water level gets too low in the internal boiler,
it can damage the heating element.
The dosage buttons must be programmed with
espresso coffee in the filter basket and with the handle locked into
the grouphead. Programmng should not occur with water only. Programming
is accomplished by holding the star button for 5 seconds (small light
will flash), and then immediately selecting the dosage button you want
to program. Once the desired amount of espresso coffee is dispensed, you press the same dosage button to stop
the dispensing. Wait 30 seconds to allow amount of espresso coffee dispensed to be saved into memory. The machine is ready
to be used or have another dosage button programmed.
Please note that if you change the grind setting to a finer grind,
it is possible that the dosage dispensed could lessen, especially if
the finer grind causes the internal over pressure valve to open sooner. |